The NeoVas® Bioabsorbable Sirolimus-Eluting Coronary Stent is a fully biodegradable scaffold that able to be gradually degrades, restoring the artery’s natural function without permanent implants.

Product features
Delivery system
  • Completely self-developed second-generation rapid-exchange balloon dilatation catheter
  • Superior pushability and crossability
Stent Platform
  • Fully degradable poly (L-lactide)
  • Sine wave structure in space, In-phase peak-valley connection
Drug
  • Classical Sirolimus with dose of 15.3 ug/mm
  • Inhibit the proliferation and migration of smooth muscle cells
Drug coating
  • Fully degradable poly (D,L-lactide)
  • Effectively control sirolimusrelease rate
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
  • Blades Working height is only 0.13mm, which could avoid blood vessel perforation
  • Pre-made longitudinal neat blades, which could reduce the risk of intimal disordered tearing
Segmented Microsurgical blades Design
  • Sharp and anti-friction blades, balance cuttingforce and flexibility
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Semi-compliant balloon
  • lmprove crossability
  • Optimize retraction
Why choose NeoVas?
  • - Avoiding long-term safety problem associated with permanent retention of metal implants

    - Avoiding imprisonment in the “metal cage” and recovering the vasomotor function

    - Performing positive remodeling and bringing late benefits to the lumen

    - Avoiding the risk of very late metal stent wire fracture

    - Not hindering the option of revascularization, and facilitating re-interventional therapy

    - Allowing MRI and CT examination at any time

    - Solving the allergic reaction of some patients to metal stent

    - Solving the psychological barrier of some patients rejecting the retention of foreign metal body

How it works
NeoVas OPC study
  • 1-2 year follow-up result
  • 2 year stent thrombus: Compare with Absorb and Xience
NeoVas RCT Study
  • The clinical result at one year follow-up
  • The clinical result at Three year follow-up
OCT: Study on stent absorption in 3 years
Product Details
  • Structure indication and technical parameters
  • Technical parameters
  • Ordering Information
  • Structure indication
    The NeoVas Bioabsorbable Sirolimus-Eluting Coronary Stent System consists of a degradable stent matrix, a degradable carrier, sirolimus, a developing platinum mark, and a balloon catheter. The structural diagram is shown above
  • Technical parameters
  • Ordering Information
    Stent Diameter (mm) Stent Length (mm)
    12 15 18 21 24
    2.75 LPS2712 LPS2715 LPS2718 LPS2721 LPS2724
    3 LPS3012 LPS3015 LPS3018 LPS3021 LPS3024
    3.5 LPS3512 LPS3515 LPS3518 LPS3521 LPS3524

    The study enrolled 560 subjects in 33 centers from china, Test group(NeoVas): 278 cases, Control group (Xxience stent): 282 cases