- Coronary Stents Coronary Balloons Catheters Guide Wires Introducer Sheaths Fractional Flow Reserve Accessories Peripheral Interventional Products Structural Heart Diseases Products 12345678
- Pacemakers and Leads Equipments
- Needle-free Connectors CVC Accessories
- Dialyzer Hemoperfutor Hemodialysis Accessories
- POCT Point of Care Testing Immunoassay Molecular Diagnostics Biochemistry Hematology Diagnostics
- ECG Patient Monitor Oximeter
- Cardiovasculars Oncology Anti-infectives Central Nervous System Others
- Surgical Staplers Endoscopy Endoscopic Ultrasound System
- Trauma Implant Spinal Implant Joint System Surgical Instruments
- Colloidal Gold Quantitative Analyzer SARS-CoV-2 Test Kits 2019-nCoV Neutralization Antibody Test Kit Poctor® blood glucose, ketone body, uric acid detector Cholesterol Analyzer PT/INR Meter
- Fully Automated ELISA workstation Immunofluorescence Quantitative Analyzer Fully Automated CLIA workstation Automatic fluorescence immunoassay analyzer Other Platforms
- Fully Automated Nucleic Acid Extractor Nucleic Acid Extraction or Purification Kit Real-Time PCR System
- Thromboelastography Analyzer Fully automated blood grouping system
- NeoECG Holter Monitor Portable ECG Monitor OmniECG AI-ECG Pocket ECG
- Patient Monitor Vital Signs Monitor End-tidal Capnography
- Fingertip Oximeter Handheld Oximeter Wrist Oximeter Wearable Oximeter All-in-One Health Monitor POCT Solution
- Locking Compression Plates System Locking Plates Screws Interlocking Intramedullary Nails System Mini Plates System Conventional Plates Metal Pins Dynamic Hip Locking Plate
- Anterior Cervical Locking Fixation System Laminoplasty Plate Fixation System Internal Spinal Fixation System Spinal Fusion System
- Instrument Set of Arthroplasty System
GuReater® CoCr Sirolimus-eluting Coronary Stent System
GuReater CoCr Stent Sirolimus-eluting Coronary Stent System Details
Product Description
GuReater is a CoCr drug-eluting stent covered with Sirolimus. Its 75 μm CoCr strut provides super flexibility and crossability to ensure great compliance after implantation.
Product Features
CoCr stent has great radiopacity and biocompatibility.
75μm ultrathin strut guarantees the excellent flexibility of the stent during delivery and helps with better endothelialization.
Low recoil ratio of 3.4% for CoCr stent ensures better stent apposition to reduce the risk of thrombosis.
PLGA biodegradable polymer coating provides precise drug-releasing control and a scientific degradation period.

75 μm ultrathin strut thickness and unique strut structure guarantee the excellent compliance of the stent during delivery.
CoCr stent has great radiopacity, and biocompatibility, and provides an excellent balance between radial strength and flexibility.
MRI compatible
Product Benefits

Clinical Evidence

Large-scale Quality Tracking Research
22 hospitals, 2,022 subjects
12 months follow-up of 1699 cases, the main follow-up was the occurrence of adverse events
50 cases had adverse events (2.94%), 2 cases died (0.12%), all of them were non-cardiac deaths, 4 cases had non-target blood vessel revascularization (0.24%)
Confirms that the GuReater® Sirolimus-eluting Coronary Stent System is safe and effective in a wide range of patients and lesion comprehensive performance. GuReater is a product with high clinical application value.
Product Ranges
2.25-4.5 mm
8-36 mm multi stent lengths
Specifications

Ordering Information

Please contact local sales for details before placing order.
Thank You for Your Attention on Lepu Medical!
Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.
