- Coronary Stents Coronary Balloons Catheters Guide Wires Introducer Sheaths Fractional Flow Reserve Accessories Peripheral Interventional Products Structural Heart Diseases Products 12345678
- Pacemakers and Leads Equipments
- Needle-free Connectors CVC Accessories
- Dialyzer Hemoperfutor Hemodialysis Accessories
- POCT Point of Care Testing Immunoassay Molecular Diagnostics Biochemistry Hematology Diagnostics
- ECG Patient Monitor Oximeter
- Cardiovasculars Oncology Anti-infectives Central Nervous System Others
- Surgical Staplers Endoscopy Endoscopic Ultrasound System
- Trauma Implant Spinal Implant Joint System Surgical Instruments
- Colloidal Gold Quantitative Analyzer SARS-CoV-2 Test Kits 2019-nCoV Neutralization Antibody Test Kit Poctor® blood glucose, ketone body, uric acid detector Cholesterol Analyzer PT/INR Meter
- Fully Automated ELISA workstation Immunofluorescence Quantitative Analyzer Fully Automated CLIA workstation Automatic fluorescence immunoassay analyzer Other Platforms
- Fully Automated Nucleic Acid Extractor Nucleic Acid Extraction or Purification Kit Real-Time PCR System
- Thromboelastography Analyzer Fully automated blood grouping system
- NeoECG Holter Monitor Portable ECG Monitor OmniECG AI-ECG Pocket ECG
- Patient Monitor Vital Signs Monitor End-tidal Capnography
- Fingertip Oximeter Handheld Oximeter Wrist Oximeter Wearable Oximeter All-in-One Health Monitor POCT Solution
- Locking Compression Plates System Locking Plates Screws Interlocking Intramedullary Nails System Mini Plates System Conventional Plates Metal Pins Dynamic Hip Locking Plate
- Anterior Cervical Locking Fixation System Laminoplasty Plate Fixation System Internal Spinal Fixation System Spinal Fusion System
- Instrument Set of Arthroplasty System
MemoPart™ Atrial Septal Defect (ASD) Occluder Details
ASD occluder device Description
MemoPartTM ASD Occluder is a self-expanding double-disc device made of nitinol mesh, stainless steel bushing(s), suture line and polyester fabric membrane. The device has a left atrial (LA) disc, a right atrial (RA) disc, and a short waist corresponding to the size of the atrial septal defect (ASD). Polyester fabric membrane is securely sewn within each disc and the waist by suture line to ensure optimal occlusion. The device is visible under X-ray.
Indications for Use ASD occluder device
Patients eligible for ASD closure display echocardiographic evidence of ostium secundum atrial septal defect and clinical evidence of right ventricular volume overload (i.e., 1.5:1 degree of left-to-right shunt or RV enlargement).
Thank You for Your Attention on Lepu Medical!
Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.
